Auto-Ranging Multimeter

Model 2700 

제품특징

제품사양

ELECTRICAL SPECIFICATIONS :
Accuracies are ±(...% of rdg + ...digits) at 23℃±5℃. > 80% RH.

DC Voltage(Autorange & manual)

Range

Resolution

Accuracy

Input
impedance

Overload
protection

320mV

0.1mV

±0.5%rdg + 2dgts

>100MΩ

AC/DC 750V

3.2V

1mV

11MΩ

32V

10mV

10MΩ

320V

100mV

600V

1V

0.8%rdg + 2dgts

AC voltage(Autorange & manual range)

Range

Resolution

Accuracy

Input
impedance

Overload
protection

3.2V

100μV

1.2%rdg + 4dgts

11MΩ

AC/DC 750V

32V

1mV

10MΩ

320V

10mV

600V

1V

DC Current( ㎂ mA Autoranging & manual)

Range

Resolution

Accuracy

Burden Voltage

Overload
protection

320㎂

0.1㎂

1%rdg + 2dgts

0.2V max

0.5A/250V
Fast Blow
fuse & Diodes

3200㎂

1㎂

1.8V max

32mA

10㎂

1.2V max

320mA

100㎂

1.8V max

20A

10mA

1.5%rdg + 2dgts

0.6V max

20A/380V Fast Fuse

AC Current( ㎂ mA Autoranging & manual)

Range

Resolution

Accuracy

Burden Voltage

Overload
protection

320㎂

0.1㎂

1.5%rdg + 5dgts

0.2V max

0.5A/250V
Fast Blow
fuse & Diodes

3200㎂

1㎂

1.8V max

32mA

10㎂

1.2V max

320mA

100㎂

1.8V max

20A

10mA

2.0%rdg + 5dgts

0.6V max

20A/380V Fast Fuse

Resistance(Ω)

Range

Resolution

Accuracy

Max.
Open circuit voltage

Overload
protection

320Ω

0.1Ω

0.8%rdg + 2dgts

1.3V

660Vrms

3.2kΩ

1Ω

32kΩ

10Ω

320kΩ

100Ω

3.2MΩ

1KΩ

30MΩ

10KΩ

1.5%rdg + 3dgts

Diode

Range

Resolution

Accuracy

Max.
Test Current

Max.
Open Circuit Voltage

Overload
protection

1mV

1%rdg + 2dgts

0.8mA

3V

660Vrms

Continuity

Range

Operating Resolution

Max. Open Circuit Voltage

Overload Protection

≤20Ω

1.3V

660Vrms

GENERAL SPECIFICATIONS :