Dual Channel Datalogging Digital Multimeter Prova803(RS-232)
|
◈ 제품특징
◈ 제품사양
ELECTRICAL SPECIFICATIONS : ( 23℃±5℃)
■ DC Voltage : (Input Impedance : 10M Ω )
Range |
Resolution |
Accuracy |
Overload Protection |
60.000mV |
0.001mV |
± 0.2% ±9 dgts 1 |
DC 1000V |
600.00mV |
0.01mV |
± 0.04% ±6 dgts 2 |
DC 1000V |
6.0000V |
0.0001V |
± 0.04% ±6 dgts |
DC 1000V |
60.000V |
0.001V |
± 0.04% ±6 dgts |
DC 1000V |
600.00V |
0.01V |
± 0.04% ±6 dgts |
DC 1000V |
1000.0V |
0.1V |
± 0.08% ±6 dgts |
DC 1000V |
■ AC voltage :
Range (ACV) |
Resolution |
Accuracy(50/60Hz) |
60.000mV |
0.001mV |
± 0.2% ±4 0dgts |
600.00mV |
0.01mV |
± 0.2% ±4 0dgts |
6.0000V |
0.0001V |
± 0.2% ±4 0dgts |
60.000V |
0.001V |
± 0.2% ±4 0dgts |
600.00V |
0.01V |
± 0.2% ±4 0dgts |
1000.0V |
0.1V |
± 0.2% ±4 0dgts |
■ DC Current :
Range |
Resolution |
Accuracy |
600.00 ㎂ |
0.01 ㎂ |
± 0.4% ±2 0dgts |
6000.0 ㎂ |
0.1 ㎂ |
± 0.2% ±2 0dgts |
60.000mA |
0.001mA |
± 0.4% ±2 0dgts |
600.00mA |
0.01mA |
± 0.2% ±2 0dgts |
1.0000A |
0.0001A |
± 0.2% ±2 0dgts |
10.000A 1 |
0.001A |
± 0.6% ±2 0dgts |
1 20A overload for maximum 30 seconds
■ AC Current :
Range |
Resolution |
Accuracy(50/60Hz) |
600.00 ㎂ |
0.01 ㎂ |
± 0.6% ±4 0dgts |
6000.0 ㎂ |
0.1 ㎂ |
± 0.6% ±4 0dgts |
60.000mA |
0.001mA |
± 0.6% ±4 0dgts |
600.00mA |
0.01mA |
± 0.6% ±4 0dgts |
1.0000A |
0.0001A |
± 0.6% ±4 0dg ts |
10.000A 1 |
0.001A |
± 0.9% ±4 0dgts |
1 20A overload for maximum 30 seconds
■ Resistance : (Ω)
Range | Resolution | Accuracy | Overload Protection |
999.99 Ω | 0.01 Ω |
± 0.25% ±9 dgts |
AC 1000V |
9.9999K Ω | 0.0001K Ω |
± 0.15% ±6 dgts |
AC 1000V |
99.999K Ω | 0.001K Ω |
± 0.15% ±6 dgts |
AC 1000V |
999.99K Ω | 0.01K Ω |
± 0.15% ±6 dgts |
AC 1000V |
9.9999M Ω | 0.0001M Ω |
± 0.3% ±9 dgts |
AC 1000V |
40.000M Ω |
0.001M Ω |
±1. 5% ±9 dgts |
AC 1000V |
■ Continuity : (Open voltage 3V aprox)
Range |
Resolution |
Beeper |
Overload protection |
999.99 Ω |
0.01Ω |
<40Ω approx |
AC 1000V |
■ Capacitance : ( ┥┝ , auto range, and for film capacitor or better)
Range |
Resolution |
Accuracy 1 |
60.00nF |
0.01nF |
±1 .2% ±8 dgts |
600.0nF |
0.1nF |
±2.5 % ±8 dgts |
6.000㎌ |
0.001㎌ |
±2.5 % ±8 dgts |
60.00㎌ |
0.01㎌ |
±3.0 % ±8 dgts |
600.0㎌ |
0.1㎌ |
±5.0 % ±8 dgts |
1 for reading less than 150 counts(least significant digits),
add additional 15 digits to the specified accuracy.
■ Capacitance : ( ┥┝ , manual range, and for film capacitor or better)
Range |
Resolution |
Accuracy 1 |
99.99nF |
0.01nF |
±1 .2% ±8 dgts |
999.9nF |
0.1nF |
±2.5 % ±8 dgts |
9.999㎌ |
0.001㎌ |
±2.5 % ±8 dgts |
99.99㎌ |
0.01㎌ |
±3.0 % ±8 dgts |
999.9㎌ |
0.1㎌ |
±5.0 % ±8 dgts |
1 for reading less than 150 counts(least significant digits),
add additional 15 digits to the specified accuracy.
■ Diode Test : (open voltage 3V approx, overload protection AC 1000V)
Range |
Resolution |
Accuracy |
Short Circuit Voltage |
3.0000V |
0.0001V |
±2%rdg ± 5dgts |
0.8mA typical |
■ Frequency : (TTL)
Range(Auto) |
Resolution |
Accuracy |
Overload Protection |
1.000Hz2MHz |
0.0001Hz-0.0001MHz |
±0.005%rdg ± 4dgts |
AC 1000V |
GENERAL SPECIFICATIONS :