3Φ PF Power Clamp Meter 

Model PROVA 6601(RMS) 


 


 

PROVA-6601
3상 파워 클램프메타


- KW, PF(COSΦ), KVA, KVAR(3Φ4W, 3Φ3W, 1Φ)
- AC+DC Ture Power, True RMS ACV, ACA
- AC+DC 1200KW(1Φ), AC+DC 2000KW(3Φ)
- Dual Display KW+PF, KVA+KVAR, V+Hz, A+V
- 위상각 (Φ), Phase Sequence Indication
- Memory of 4 Records
- DCA/DCW Auto Zero
- Auto Range V, A, W : AC/DC Auto Detection
- AC+DC True Power : 0 ~ 1200KW
- AC+DC 전압 : 0 ~ 600V
- AC+DC 전류 : 0 ~ 2000A
- AC+DC KVAR : 0 ~ 1200KW
- 클램프 크기 : Cable Φ55mm, Bus Bar 65mm(D)x24mm(W)
- 배터리 : 9V
- 디스플레이 : 2 x 4 Digits Dual Display LCD
- 범위 선택 기능 : 자동
- 과부하 경고 기능 : "OL"
- 소모전력 : 25mA(approx.)
- 크기 : 271mm(L) × 112mm(W) × 26.2mm(H)
- 무게 : 647g(batteries Included)
- 악세사리 : 휴대용가방, 사용설명서, 9V 배터리, 테스트리드선

 

제품특징

제품사양

ELECTRICAL SPECIFICATIONS : (23℃±5℃)

AC+DC True Power
(PF 0.2-1.0, 3Φ3W, 3Φ4W, 1Φ2W and 1Φ3W) :


Range

Resolution

Accuracy (of rdg)

Input Range

0~99.9KW

0.01KW

±2.0%±0.05KW

AC600V,DC800V
ACA/DCA 2000A

100~999.9KW

0.1KW

±2.0%±0.5KW

AC600V,DC800V
ACA/DCA 2000A

1000~1200KW

1KW

±2.0%±5KW

AC600V,DC800V
ACA/DCA 2000A


AC+DC Voltage

(True RMS, Crest Factor<4, Autorange, Overload Protection 800VAC for all range)


Range

Resolution

Accuracy( of reading)

Input impedance

DC. 50/60

Hz 40~400Hz

0~200V

0.1V

±1.5%±5dgts

±2.0%±5dgts

10MΩ

200~500V

0.1V

±1.5%±5dgts

±2.0%±5dgts

10MΩ

500~600V

1V

±1.5%±5dgts

±2.0%±5dgts

10MΩ


AC+DC A (True RMS, Crest Factor < 4)


Range

Resolution

Accuracy( of reading)

Overload Protection

DC. 50/60

Hz 40~400Hz

0~200A

0.1A

±1.5%±5dgts

±2.0%±5dgts

AC 3000A

200~500A

0.1A

±2.0%±5dgts

±2.5%±5dgts

AC 3000A

500~2000A

1A

±2.5%±5dgts

±3.0%±5dgts

AC 3000A


AC+DC KVAR (Reactive Power, 3Φ3W Sine Wave)


Range

Resolution

Accuracy (of KVA rdg)

Input Range

0~99.99KW

0.01KW

±2.0%±0.05KW

AC 600V, DC 800V
ACA/DCA 2000A

100~999.9KW

0.1KW

±2.0%±0.5KW

AC 600V, DC 800V
ACA/DCA 2000A

1000~1200KW

1KW

±2.0%±5KW

AC 600V, DC 800V
ACA/DCA 2000A


Phase angle (must zero current reading before measurement 6600)


Range

Accuracy

Sensitivity

Remake

50/60Hz

±2.0

V>100V, A>10A



Frequency(Hz) (if < 10 Hz , Hz = 0)


Range

Accuracy

Sensitvity

50/60Hz

±2dgts

V>1V, A>5A

10~400Hz

±0.5%±2dgts

V>1V, A>5A


Function List of PROVA 6600 and 6601


Function

Condition/range

6600

6601

KW, PF

3Φ3W

Balanced Load

KVA, KVAR

3Φ3W

Balanced Load

KW, PF

3Φ3W

Unbalanced Load

×

KVA, KVAR

3Φ3W

Unbalanced Load

×

KW, PF

3Φ4W

Balanced/Unbalanced Load

KVA, KVAR

3Φ4W

Balanced/Unbalanced Load

×

Phase Angle(Φ)

±90°

×

Phase Sequence Indication

RST or TSR

×

KW, PF, KVA, KVAR

V(True RMS)

AC+DC 600V

A(True RMS)

AC+DC 2000A

Hz(V>1)

10.0~400.0Hz

Hz(A>5)

10.0~400.0Hz

×


GENERAL SPECIFICATIONS :